GSA Historic Preservation Technical Procedures certified

GSA Historic Preservation Procedures

U.S. Patent 6991400 certified

U.S. Patent 6991400

Lead Flashing for Brick and Masonry Joint Protection

This category features WEATHERCAP® patented soft lead joint protection systems for masonry and brick construction, including Type A flat caps and Type B 90° cove caps in stock and application-specific configurations. These products act as an adjunct to caulk/sealant, absorbing building movement, resisting corrosion and mold, and extending sealant life across copings, cornices, window/door joints, and entrance steps.

WEATHERCAP A-8 Type A Flat Joint Cap
WEATHERCAP B-8 Type B 90° Cove Cap
WEATHERCAP A-6 Type A Flat Joint Cap
WEATHERCAP B-4 Type B 90° Cove Cap
WEATHERCAP A-2 Type A Flat Joint Cap
WEATHERCAP B-3 Type B 90° Cove Cap
WEATHERCAP B-2 Type B 90° Cove Cap
WEATHERCAP B-6 Type B 90° Cove Cap
WEATHERCAP A-3 Type A Flat Joint Cap
WEATHERCAP A-4 Type A Flat Joint Cap
WEATHERCAP Entrance Step Joint Protection
WEATHERCAP Portico, Bracket and Pilaster Joint Protection
WEATHERCAP Water Table Joint Protection
WEATHERCAP Window and Door Frame Joint Protection
WEATHERCAP Balustrade Joint Protection
WEATHERCAP Window Sill Joint Protection
WEATHERCAP Joint Protective System (Lead Stone Flashing / Tee Caps)
WEATHERCAP Type A Flat Joint Cap
WEATHERCAP Lead Arrowhead Masonry Joint Caps
WEATHERCAP Corner and Fillet Joint Protection
WEATHERCAP Glass Block Perimeter Joint Protection
WEATHERCAP Horizontal and Vertical Masonry Joint Protection
WEATHERCAP New Construction Masonry Joint Protection
WEATHERCAP Cornice and Belt Course Joint Protection
WEATHERCAP Type B 90° Cove Cap
WEATHERCAP Window and Door Lintel Joint Protection
WEATHERCAP Coping and Parapet Joint Protection
WEATHERCAP Building Movement and Joint-Checking Protection
WEATHERCAP Historic Masonry Preservation Joint Protection
WEATHERCAP Custom and Large-Size Masonry Joint Caps
WEATHERCAP Masonry Moisture Penetration Protection
WEATHERCAP Masonry Sealant Protection System

Our Range of Products

WEATHERCAP A-8 Type A Flat Joint Cap

WEATHERCAP A-8 Type A Flat Joint Cap

  • A-8 flat cap for joints up to 1 1/2 in
  • Heavy-duty 2.5 lb/ft lead construction
  • Wide 2 in outer coverage area
WEATHERCAP B-8 Type B 90° Cove Cap

WEATHERCAP B-8 Type B 90° Cove Cap

  • B-8 cove cap for joints up to 1 1/4 in
  • Heavy-duty 2.5 lb/ft lead construction
  • Perpendicular anchorage, 1 3/4 in coverage
WEATHERCAP A-6 Type A Flat Joint Cap

WEATHERCAP A-6 Type A Flat Joint Cap

  • A-6 flat cap for joints up to 1 1/4 in
  • Wide 1 1/2 in outer coverage area
  • 0.83 lb/ft, standard 6-ft lengths
WEATHERCAP B-4 Type B 90° Cove Cap

WEATHERCAP B-4 Type B 90° Cove Cap

  • B-4 cove cap for joints under 5/8 in
  • Horizontal and perpendicular anchorage options
  • 0.40 lb/ft, supplied in 6-ft lengths
WEATHERCAP A-2 Type A Flat Joint Cap

WEATHERCAP A-2 Type A Flat Joint Cap

  • Compact A-2 flat cap for narrow joints
  • Joint size under 3/8 in, new construction
  • Lightweight at 0.26 lb/ft
WEATHERCAP B-3 Type B 90° Cove Cap

WEATHERCAP B-3 Type B 90° Cove Cap

  • B-3 cove cap for joints under 1/2 in
  • Horizontal and perpendicular anchorage
  • Lightweight 0.22 lb/ft lead strip

Showing 1 to 6 of 32 results

Frequently Asked Questions

What is the purpose of brick flashing?

Brick flashing directs water away from vulnerable masonry joints and protects the caulk or sealant beneath it from UV exposure, temperature swings, and physical wear. Lead flashing caps like WEATHERCAP reduce the effective opening of a sealant joint, cover the sealant to slow degradation, and flex with building movement to prevent leaks and cracking at copings, cornices, lintels, and sills.

How do you attach flashing to brick?

What is the difference between Type A and Type B lead joint caps?

Why is soft lead used instead of rigid metal flashing?

Can lead joint caps be used on new construction and restoration projects?

What safety precautions apply when handling lead flashing?

How do I determine the correct size of lead joint cap for my project?

Didn't find what you're looking for?

Talk to our experts for custom solutions and tailored guidance.

Industries We Serve

Historic Preservation & Restoration Contractors

Historic Preservation & Restoration Contractors

Protects sealant in copings, cornices, and lintels during restoration of landmark masonry facades and structures.

New Construction Masonry Contractors

New Construction Masonry Contractors

Installed in new masonry joints to prevent future sealant failure from building settlement and movement.

Architects Specifying Masonry Details

Specified into construction documents for copings, parapets, lintels, and window/door joint protection details.

Government & Institutional Preservation Bodies

Government & Institutional Preservation Bodies

Used on federal and institutional landmark buildings under GSA historic preservation technical procedures.

Didn't find what you're looking for?

Talk to our experts for custom solutions and tailored guidance.

Why restoration contractors and architects choose Weathercap

Patented Lead Flashing Technology

U.S. Patent 6991400 protects a soft lead system engineered to flex with building movement and prevent joint failure.

Proven on Landmark Structures

Specified on the Washington Monument, U.S. Supreme Court, and Smithsonian Institution, demonstrating long-term field performance.

Rapid Order Fulfillment

Full manufacturing and supply chain operations ship 6-foot lengths within 48 hours of order placement.

Request Technical Specifications and Pricing for Lead Flashing

Submit your project details and a specialist will follow up with sizing guidance, CAD drawings, and pricing for your masonry joint application.

Contact Us Today

For immediate assistance, feel free to give us a direct call at (985) 649-4000.