(985) 649-4000 Request information

Installing lead stone flashing to protect masonry joints.

U.S. General Services Administration, Historic Preservation Technical Procedures 07656-01.

Part 1, General

1.01 Summary

  1. This procedure includes guidance on weatherproofing vulnerable masonry joints by embedding a soft lead strip into a caulking compound or sealant filled joint.
  2. This type of work is often necessary when unknown building movement causes the failure of existing joint caulk or sealant in locations such as a masonry or stone parapet, coping, balustrade, railing, cornice, belt course ledges, or any other exterior masonry or stone feature where the top surface is exposed. This also includes corner and fillet joints where a horizontal surface joins a vertical surface, with horizontal protection extending down over front and back edges 2 in. or to an appropriate stopping point to protect the exposed corner.
  3. See 01100-07-S for general project guidelines to be reviewed with this procedure: safety precautions, historic structures precautions, submittals, quality assurance, delivery, storage and handling, project and site conditions, sequencing and scheduling, and general protection. Follow them, when applicable, along with recommendations from the Regional Historic Preservation Officer (RHPO).

1.02 System description

  1. Stone flashing is a weatherproofing product, manufactured from lead, designed to be used with a building sealant for the weatherproofing and protection of masonry joints. It consists of a molded cap or fillet surface with a splined tang for anchoring in the sealant filled mortar joint, manufactured in a selection of sizes and in continuous strips for field cutting and fitting.

1.03 Submittals

  1. Manufacturers' information, shop drawings (manufacturer's standard detail sheets), materials lists and certificates for the products proposed for use.
  2. Samples: 12 in. long pieces of each type of stone flashing proposed for use.

1.04 Quality assurance

  1. Restoration specialist: work must be performed by a firm with not less than 5 years of successful experience in comparable masonry restoration projects, employing personnel skilled in the restoration processes and operations indicated.

1.05 Warranty

  1. Provide copies of all manufacturer's guarantees of materials and installation, duly signed and dated.
  2. Include all warranty inspections by a manufacturer's representative necessary to effect the guarantee of material performance and its installation.

Part 2, Products

2.01 Manufacturers

  1. WEATHERCAP®, Inc., P.O. Box 1776, Slidell, LA 70459-1776, (985) 649-4000.

2.02 Materials

  1. Tee caps: lead stone flashing strips (WEATHERCAP®, Inc.), or approved equal.
    1. Use size of strips as recommended by the sealant manufacturer and compatible with the style and configuration of existing.
    2. Strips should be of sufficient size to cover the joint width, plus a percentage allowance for anticipated joint movement, plus 1/4 in.
  2. Sealant: see also 07900-01-S for guidance. Test to make sure the sealant does not stain masonry.

2.03 Equipment

  1. 1 in. masking tape
  2. Putty knife
  3. Heavy gloves

Part 3, Execution

3.01 Examination

  1. Determine the extremes of joint movement using a scribe kit (available from the sealant manufacturer). Measurement of anticipated and known joint movement is necessary in determining the appropriate size of tee cap to use.

3.02 Preparation

  1. Verify that joints to have stone flashing strips are raked or cut out to the correct depth and clean.

3.03 Installation

Wear gloves when working with lead products and wash hands thoroughly when finished with work.

  1. Fitting tee cap:
    1. Mark off the width of the selected tee cap on the masonry or stone surface and apply 1 in. masking tape lateral to the marks.
    2. Pre-fit or shape and cut tee cap strips to closely conform to the profile of the stone substrate as required before setting.
    3. Select a width to overlap joint edges not less than 1/8 in.
    4. Cut strips to lay in a single full length in each joint wherever possible, with an end turn-down over front and back faces of ledges and copings a minimum of 1 in. or to the drop edge.
    5. Make all joints in the tee cap neatly mitered, coped or butted to produce close fitting, weather resisting joint protection. Notch strips as recommended by the manufacturer.
    6. Apply metal primer to the tee cap if required.
  2. Sealing and installing tee cap. Install sealants in accordance with the manufacturer's recommendations.
    1. If required, install backer rod to a depth of 1/4 in. below the tip of the anchor shaft when the tee cap is set in place.
    2. Prime stone, if required.
    3. Fill the joint with sealant to a height of approximately 1/8 in. above the adjacent masonry surface. Follow the manufacturer's instructions.
    4. Set the preformed tee cap strip into the sealant bed, pressed down firmly to the stone surface so bonding grooves are solidly filled and no voids exist between tee cap and masonry.
    5. Clean off excess sealant compound using a putty knife and leave adjacent masonry clean.
    6. Carefully remove masking tape from adjacent surfaces.

Editing this for your project?

We can send the specification pages and answer questions on sizes and anchorage.

(985) 649-4000Call Slidell, Louisiana
(985) 847-1237Fax
P.O. Box 1776, Slidell, LA 70459-1776Mailing address

Request information

Fields marked * are required.

Please enter your name.

Enter an email like name@firm.com.

Please enter a phone number.

Tell us when to call.

We use your details only to answer this request.

Request received.

Thank you. WEATHERCAP® will be in touch at the time you chose. For anything urgent, call (985) 649-4000.