Identification

Trade name
WEATHERCAP®
Information furnished by
WEATHERCAP®, Inc.
Address
P.O. Box 1776, Slidell, LA 70459
Emergency phone
(985) 649-4000
Date effective
4/15/89

Section 02, Constituents

Chemical
Lead
% by weight
99.9
Carcinogen
No
Note
Contains a chemical subject to Section 313 of SARA Title III

Section 03, Physical data

Melting point
327°C (621°F)
Boiling point
N/A
Vapor pressure
Not volatile
Solubility in water
Nil
Appearance and color
Silver grey metal
Specific gravity
11.34
Odor
Odorless

Section 04, Fire and explosion

Flash point
Not flammable
Fire-fighting
If this metal is present in a fire, wear self-contained breathing apparatus in case of lead fumes
Special precautions
None

Section 05, Reactivity

Stability
Stable
Hazardous polymerization
Will not occur
Incompatibility
Strong oxidizers
Hazardous decomposition
Toxic lead fumes above 750°F

Section 06, Spill and disposal

Spills and leaks
Allow to solidify and collect in sealed drums for disposal
Disposal method
Return to supplier for reprocessing

Section 07, Health hazards

Eye
Mechanical irritant from dust or fume
Skin contact and absorption
Not a route of entry into the body
Ingestion
Lead is toxic and cumulative, affecting the blood forming activity, kidneys and nervous system. Symptoms include anemia, insomnia, weakness, irritability, stomach pains, etc.
Inhalation
Inhalation of dust or fume must be avoided. Irritation of nose and throat may occur as well as effects due to absorption of lead into the body

Section 08, First aid

Eyes
Flush with water for 15 minutes. Get medical attention
Skin
Wash thoroughly with soap and water
Ingestion
If person is conscious, induce vomiting and get medical attention
Inhalation
Remove to fresh air. If person is not breathing apply artificial respiration. Get medical attention

Section 09, Handling

Ventilation
If fume or dust is generated, mechanical and local ventilation is essential
Respiratory protection
Only if TLVs are exceeded. Use a fume mask
Eye protection
Safety glasses or face shield when handling molten metal
Skin protection
Not normally needed

Section 10, Precautions

Storage
Store in dry condition
Regulation
Lead is regulated under OSHA 29 CFR 1910.1025. No food or drink where these products are handled. Wash thoroughly after handling, before eating, drinking or smoking

This information is given in good faith, but no warranty, express or implied, is made. It relates only to the specific material and not to use in combination with any other material or process. See the full disclaimer in the PDF.

Tell us about the joint.

Ask for pricing, specifications, CAD drawings or the MSDS. We reply by phone or email, at the time that suits you.

(985) 649-4000Call Slidell, Louisiana
(985) 847-1237Fax
P.O. Box 1776, Slidell, LA 70459-1776Mailing address

Request information

Fields marked * are required.

Please enter your name.

Enter an email like name@firm.com.

Please enter a phone number.

Tell us when to call.

We use your details only to answer this request.

Request received.

Thank you. WEATHERCAP® will be in touch at the time you chose. For anything urgent, call (985) 649-4000.